Guldmann gh2 user manual




















Solutions for your field of work. See all. News News News News 9. By supplying beds and lifting equipment as well as services that include advice and education, Guldmann works to ensure the optimum utilisation of resources in the care system, helping create more time to care. Guldmann operates worldwide and all products are manufactured in their own factories. At its launch in the GH2 model set new benchmarks and quickly gained wide support with its small discreet modern design and advanced technical features.

The GH2 offered first class user-friendly ergonomic features including: powerful batteries; excellent lifting capacities; up to lifts per charge and sophisticated safety systems. In addition the comprehensive rail systems with switch tracks; Combilock Gates and even the introduction of continuous charging rails, ensured the GH2 models raised the bar in terms of providing increased security and comfort for users and cares.

Guldmann first started thinking about the next generation of assistive technology to replace the GH2 models, way back in Guldmann undertook extensive surveys of customers, users, care professionals and key decision-makers in the care sector. The new GH3 concept is the seventh generation of Guldmann ceiling hoist technology. Wiping the design slate clean and beginning afresh with a new generation of thinking, combined with the very latest technologies and manufacturing techniques, gave Guldmann a unique opportunity to take a major step forward in ceiling hoist technology.

The new GH3 design and technology set dramatically new benchmarks for what can be achieved with modern ceiling hoist systems, both in terms of appearance and how well they can do their job. Release the axle journal 3. Mount the lifting strap 1 on the lifting hanger 4. Introduce the axle journal again 3. Use a 1. Page 7 3. Slings made by other manufacturers Guldmann shall not be liable for faults or accidents that occur as a result of using a lifting sling made by other manufacturers.

If you are in doubt about the choice or use of lifting sling, please contact your supplier. Guldmann shall not be liable for faults or accidents due to incorrect use of the lifting sling, or for reasons of inadequate attention on the part of the carer or user.

The user should only be lifted just clear of the underlying surface and should be moved at this height. Attach the lowermost set of straps from the legs to the hooks that face away from the user. Lifting to and from sitting position When lifting a user from e. As for the sling types Active, the strap showing the size of the sling should be opposite the spine. Cross the leg straps over each other in front of the user. All four lifting straps are now ready to be attached to the lifting hanger. Now attach the lifting sling to the lifting hanger.

All four lifting straps are now ready to be attached and the lifting sling can now be mounted on the lifting hanger. It is an advantage to elevate the head of the bed so that the user is sitting up. The measures regarding ESD-safety are valid in this connection. Emergency stop device The emergency stop device must be reset to zero in order to connect power to the product. To do this, push the contact arm, to which the red emergency stop band is fastened, towards the product until it clicks.

Power supply GH2 F is equipped with batteries that require regular recharging. The charger supplied must always be used. Safety in connection with static electricity ESD Service technicians and installers must use an ESD-safety package consisting of a mat, a ground wire, and a bracelet. He must then put on the bracelet and connect it to the mat.

If the technician is using a ladder, it is important that the mat is placed on the step on which he is standing. If it is not possible to find a grounding point, the mat and the bracelet must be used as a minimum. Only then is it allowed to work with the PC Board or components where it is possible to come into contact with the PC Board. Indicator lamps The colours and functions for GH2 F are as described below. On: Blinking: Off: The hoist is active The batteries are running low and must be recharged The hoist is switched off Yellow When GH2 F is being recharged, the yellow charging indicator on its information face is illuminated.

The indicator lamp flashes while the batteries are being recharged. On: The lamp will light up briefly when connected to the charger, irrespective of the state of the battery.

This indicates that there is a correct connection between GH2 F and the charger. Installing and deinstalling the lifting module 2. GH2 F is charged with the help of the DC connection on the hand control, point 9. Check that there are no obstacles of any kind between GH2 F and the travelling trolley.

Installation is begun by briefly activating the toggle switch on the hand control, direction UP 4. Installation has been completed when GH2 F is automatically locked in the travelling trolley 5. Place the transport trolley beneath the travelling trolley in the rail system. Check that there are no obstacles of any kind between GH2 F and the transport trolley. Lift the strap with the hanger towards the end stop on GH2 F 2. Deinstallation is begun by briefly activating the toggle switch on the hand control, direction DOWN 4.

Deinstallation has been completed when GH2 F is on the transport trolley and the movement of the cord has stopped 5. Please note All deinstallation must be begun by briefly moving GH2 F seconds in an upward direction. It changes states each time it is activated.

Avoid unnecessary contact with the lock. Contact the Guldmann Service Team if it appears that the lock may be damaged. Check that the switch at the bottom of the hand control is placed in position 2. The GH2 F hoist will automatically switch off after approximately ten minutes when not in use. Note There must be a load on GH2 F corresponding to the weight of a Guldmann lifting hanger before the lowering function will work.

Note GH2 F must not be exposed to cold or heat shock, so a cold lifting module should never be taken into a warm bathroom or similar.

The emergency stop and emergency lowering functions should be used only in an emergency. If, contrary to expectation, it becomes necessary to use the emergency functions, the fault must be located and remedied before using GH2 F again. Please contact your supplier.

EMC If electromagnetic or other influences occur between this product and other products, these products must not be used together. GH2 F will not function when the emergency stop has been activated. Emergency lowering If GH2 F breaks down, the electrical emergency lowering device can be used to lower the user safely. The emergency lowering device is operated by a constant pull on the red strap which is also used to activate the emergency stop.

If the red strap is not pulled continuously, the emergency lowering function will be replaced by an emergency stop. It will therefore not be possible to activate GH2 F in any other way.

If this happens, GH2 F will stop briefly and then move freely in the direction of the travelling trolley. This means that the movement of the cord must have stopped and the installation motor must be inactive. Avoid unnecessary contact with the sensor.

Contact the Guldmann Service Team if it appears that the sensor has been damaged. If the yellow mark on the strap is visible, do not lift with maximum load. Recharge GH2 F every night, or when not in use. This is the best way to maintain the batteries and ensure as long a lifetime as possible. A pre-installed male plug on the connection side, appropriate for the mains system in the country in question, will protect the charger against incorrect use.

Connect the spiral wire to the hand control in the place indicated by the 24V DC label 1. Hand control switches will be switched off when connecting the charger DC plug. GH2 F cannot be recharged via the rail system. Page 19



0コメント

  • 1000 / 1000